50
DCU 410 Engine Panel Installation
400 Series Installation and Configuration
4-20 mA
First, select any of the four 4-20 mA channels. Then, for
each selected channel, set the following.
General
Channel Use
This selects the panel the instrument widget is
displayed on. It is possible to display the
instrument on
o
the DCU engine panel, and
o
the RP remote panel, or
o
a combination of the two.
It is also possible to suppress the alarm events, as
can be seen in the following table overview.
Use
DCU
RP
Config.
outputs
Display
Event
Display
Event
Not in use
Event
x
x
x
DCU
x
x
DCU + Event
x
x