400 Series Installation and Configuration
DCU 410 Engine Panel Installation
75
Make sure the IP-address is unique on the network. If
installing the DCU in an already established ship Ethernet,
consult the network manager to obtain an IP-address.
Note! The last two digits becomes the engine number, as
part of the engine name.
Example
The Engi
ne name is “Auxiliary”, the
IP-address is selected
as 192.168.0.110. The engine name then becomes
“Auxiliary #10”.
J1939/CANopen
The DCU has an inbuilt CANopen communication
interface. This port can be used as a second J1939
interface.
Baudrate
Set the Baudrate (communication speed) for the CANopen
interface the DCU is connected to on COM 5.
Typical setting:
125kbps
Node ID
Set the Node ID for the DCU CANopen interface.
Typical setting:
Unique integer number from other CANopen nodes
on the same network.
Download EDS file
Select this to download an EDS file.
Modbus RTU
The DCU has an inbuilt Modbus RTU communication
interface.
Power
Power the optocoupled interface with 24VDC.