To read measured open data, short data or load data, use the command given below.
•
“OUTPCALC{1-3}?” on page 373
You can calculate the user calibration coefficients by entering open data, short data and
load data (data read by the above or a similar command). To enter data, use the command
given below.
•
“INPUCALC{1-3}” on page 320
NOTE
Enter data after setting the standard values used in measuring the data because these values
are needed to calculate user calibration coefficients.
NOTE
To use the input data, you need to enter all of the open data, short data and load data. At the
instant when all the data are entered, the calibration coefficient is automatically calculated
and stored in volatile memory. Therefore, you don't need to execute the “CALDON”
command if you enter all the data.
NOTE
Enter data after making settings identical to the data measurement points (fixed
measurement points, user-selected measurement points) set at the time when the input data
were acquired. In addition, in the case of user-selected measurement points, enter data after
making sweep settings identical to the data measurement points.
Example 4-2 shows a sample program for measuring data to be used for calculating a user
calibration coefficient. This program is given the file name user_cal.bas and is stored on
the sample program disk.
After you enter standard values for open data, short data and load data, this program
measures open data, short data and load data, calculates the user calibration coefficient, and
stores it in volatile memory.
Lines 50 to 110
These lines distinguish between the external controller and Instrument
BASIC and set the GPIB address and the select code.
Line 120
This line substitutes the selection of data measurement points to the
variable Cal_point$.
Lines 160 to 190 These lines reset the Agilent 4294A and then set data measurement
points to Cal_point$.
Lines 230 to 280 These lines use the subprogram Inp_data to acquire standard values for
open data, short data, and load data.
Lines 290 to 340 These lines prepare the standard values you entered for subsequent
use. The open standard capacitance needs to be in femtofarad, so these
lines make necessary conversion.
Lines 380 to 390 These lines set 1 to Bit 8 of the instrument event status register (the bit
for the completion of the measurement of calibration data and
compensation data) and to Bit 2 of the service request enable register
so that SRQ can be used.
Lines 410 to 480 These lines measure open data, short data and load data by using the
subprogram FNUser_cal. If an error is detected after any
measurement, the program is terminated.
Lines 500 to 520 These lines calculate the user calibration coefficient and store it in
Summary of Contents for 4294A
Page 4: ...4 ...
Page 18: ...18 Contents ...
Page 24: ...24 Chapter1 To make effective use of this manual Other manuals attached to this unit ...
Page 94: ...94 Chapter6 Reading Writing Measurement Data Reading Writing Data ...
Page 110: ...110 Chapter7 Processing Measurement Results Analyzing Measurement Results ...
Page 136: ...136 Chapter10 Handling Errors Sample program for error handling ...
Page 246: ...246 13 Application Sample Programs File Transfer Function ...
Page 254: ...254 Chapter15 Setting the Display LCD Sample program for setting the LCD screen ...
Page 507: ...Index Index 507 Index ...
Page 508: ...508 Index Index ...
Page 509: ...Index Index 509 Index ...
Page 510: ...510 Index Index ...
Page 511: ...Index Index 511 Index ...
Page 512: ...512 Index Index ...
Page 513: ...Index Index 513 Index ...
Page 514: ...514 Index Index ...
Page 515: ...Index Index 515 Index ...
Page 516: ...516 Index Index ...
Page 517: ...Index Index 517 Index ...
Page 518: ...518 Index Index ...