Setting Measurement Conditions
Setting the On-screen Arrangement
1. Ch
apter
T
itle
2.
Ch
ap
te
r
T
itl
e
3
. Se
tt
ing
M
e
as
ur
em
e
n
t
4
. Chap
te
r T
itle
5. Chap
te
r T
itle
Conditions
Setting a display scale
If both a data trace and a memory trace are concurrently displayed, you can separately set
different scales to these traces. Use the commands given below to specify whether to use
the same scale for both data and memory traces or to specify which trace to set a scale to
when not using the same scale.
•
“SCAC” on page 422
•
“SCAF” on page 422
NOTE
The commands above are closely related to displaying a trace, that is, there can be
instances in which executing these commands for a purpose other than properly setting a
display trace causes an error; for example, changing the settings of the trace to display also
changes other items in a linked manner. Therefore, you need to carefully plan the sequence
of executing commands in writing a program.
Three ways of setting a display scale are available depending on the display format to be
set with the command given below. Accordingly, you need to set a display format before
setting a display scale.
•
“FMT” on page 315
NOTE
The display format you can choose varies depending on the measurement parameters.
NOTE
Settings for the display scale and display format are set for each parameter. That is, the
settings are determined by the parameters selected in the active trace at the time the settings
are made, and are not the settings for trace A or trace B.
The following sections describe the method used for each type of format.
Linear/log Y-axis format
Since the display scale of the X-axis depends on the sweep settings, only set the display
scale of the Y-axis (the axis showing the measurement parameter). To set the scale, choose
the scale parameter by using one of the commands given below.
•
“SCAL” on page 423
•
“REFP” on page 408
•
“REFV” on page 409
•
“TOPV” on page 456
•
“BOTV” on page 273
In the case of a log Y-axis, however, you can only make the settings with the “TOPV” and
“BOTV” commands. The relations between the commands and the scale parameters are
shown in Figure 3-1.
Summary of Contents for 4294A
Page 4: ...4 ...
Page 18: ...18 Contents ...
Page 24: ...24 Chapter1 To make effective use of this manual Other manuals attached to this unit ...
Page 94: ...94 Chapter6 Reading Writing Measurement Data Reading Writing Data ...
Page 110: ...110 Chapter7 Processing Measurement Results Analyzing Measurement Results ...
Page 136: ...136 Chapter10 Handling Errors Sample program for error handling ...
Page 246: ...246 13 Application Sample Programs File Transfer Function ...
Page 254: ...254 Chapter15 Setting the Display LCD Sample program for setting the LCD screen ...
Page 507: ...Index Index 507 Index ...
Page 508: ...508 Index Index ...
Page 509: ...Index Index 509 Index ...
Page 510: ...510 Index Index ...
Page 511: ...Index Index 511 Index ...
Page 512: ...512 Index Index ...
Page 513: ...Index Index 513 Index ...
Page 514: ...514 Index Index ...
Page 515: ...Index Index 515 Index ...
Page 516: ...516 Index Index ...
Page 517: ...Index Index 517 Index ...
Page 518: ...518 Index Index ...