The CompuMask will also enter a Violation Gauge Mode 5 minutes after surfacing from a
dive in which a Delayed Violation occurred.
Violation Gauge Mode on the Surface does not allow access to the SET F, PLAN,
FLY, and SAT features/screens.
The countdown timer that appears when you try to access the FLY screen does not repre-
sent Time to Fly. It is only provided to inform you of the time remaining before normal
operation can resume with full CompuMask features and functions.
In the event that a dive is made during the 24 hour period following the dive, a full 24
hour surface interval must then be served before all functions are restored.
HIGH PO2 (PARTIAL PRESSURE OF OXYGEN)
When PO2 becomes equal to or greater than 0.20 (ATA) less than the PO2 Alarm Set
Point (a SET A selection); the Audible Alarm will sound (10 seconds).
> The graphic PO2 will replace the time displayed on the
lower/right (DTR) and the UP Arrow will appear solid on
the MAIN Display (Fig. 86) as a warning.
> After the Audible stops (10 seconds), the graphic PO2 will
be replaced by the DTR time, if PO2 is less than the Alarm
Set Point. The Up Arrow will remain On until PO2
decreases to 0.20 (ATA) less than the PO2 Alarm Set Point.
The PO2 value can be viewed by pressing/releasing the A
(Top) button 2 times to access the ALT 2 screen.
Fig. 86 - HIGH PO2 MAIN