Transmitter Low Battery
As previously described, if the voltage of a Linked Transmitter
decreases to the Warning level (< 2.75 volts > 2.50 volts), the
Transmitter Low Battery Status screen will appear and alternate
with the SURF MAIN. If voltage decreases to the Alarm level (<=
2.50 volts), the Lo and bAt graphics will flash.
Information displayed includes (Fig. 16):
> Graphic trtr (meaning Transmitter).
> Link (speaker) icon.
> Graphics Lo and bAt, flashing if an Alarm Condition.
SET MODES
Unless noted otherwise, items set apply to all Operating Modes
(NOR, GAU, and FRE). FRE Dive Mode also has several settings
that do not affect NOR and GAU Modes.
SURF MAIN > SET G > SET F > SET A > SET U > SET T > SN
Access and step through of the sequence is gained by repeated
2 second presses then releases of the S (Side) button.
FO2 Default (Set F), Backlight (Set G), Alarms (Set A), Utilities
(Set U), and Time (Set T) Set Points can also be set/changed
using the PC Settings Upload program. FO2 (Set F) can only be
set using the push buttons, not by using the PC Interface.
Fig. 16 - TRANSMITTER
BATTERY LOW
Upon access to a
Set Menu, the
Backlight will come
ON if OFF and
remain ON until
exit from the Set
Menu.
It cannot be turned
OFF.
Exit from the Set
Sequence to the
Main by depressing
A for 2 sec