ASCENT RATE ALARM
Alarms associated with Ascent Rate are based upon 2 sets of
speeds which change at a reference depth of 60 FT (18 M).
The Audible will sound and the graphic SLO will flash in place
of DTR (Fig. 65). The Audible will stop when acknowledged by
pressing and releasing the A (Top) button, or after 10 seconds,
or when the Ascent is slowed. The graphic will continue to flash
until Ascent is slowed, then DTR (hr:min) will reappear.
WARNING: At depths greater than 60 FT (18 M),
Ascent Rates should not exceed 60 FPM (18
MPM). At depths of 60 FT (18 M) and shallower,
Rates should not exceed 30 FPM (9 MPM).
TANK PRESSURE ALARMS
Alarms associated with Pressure are set prior to dives utilizing
the NOR/GAU Set A menu selections.
The Audible will sound and the graphic trn then End will flash
in place of DTR (Fig. 66A/B). The Audible will stop when
acknowledged by pressing and releasing the A (Top) button, or
after 10 seconds. The graphic(s) will flash for 10 seconds, then
DTR (hr:min) will reappear.
Fig. 65 - ASCENT RATE
ALARM
Fig. 66B - END PRESSURE
ALARM
Fig. 66A - TURN PRESSURE
ALARM