SET F GROUP (FO2)
Set F Sequence:
SET F > FO2 > FO2 Default.
> Depressing the S (Side) button for 4 seconds while the NOR
or GAU SURF MAIN screen is displayed will access SET F
identified by the graphic SEtF (Fig. 19).
> Pressing and releasing the A (Top) button momentarily (< 2
seconds) while SET F is displayed will access the SET FO2
screen with the Set Point flashing.
> Depressing the A (Top) button for 2 seconds while SET F is
displayed will exit the Set Menu and revert to the SURF MAIN.
Setting FO2 for NOR Nitrox Dives:
For each numerical value of FO2 displayed, the MOD (Maximum Operating Depth) that
can be achieved for the PO2 Alarm Set Point limit previously set will be displayed.
NOTE: The MODs will change if the PO2 Alarm Set Point is changed
after setting FO2.
When the FO2 DEFAULT is set ON and FO2 is set for a numerical value, 10 minutes after
surfacing from that dive FO2 will be displayed as 50 (%) and further repetitive dives will
be calculated based on 50% O2 for oxygen calculations and 21% O2 for Nitrogen
calculations (79% Nitrogen), unless FO2 is set to another numerical value before the dive.
Fig. 19 - SET F (FO2)