DELAYED VIOLATION # 1 (Fig. 82)
If you remain above the Required Deco Stop Depth for more
than 5 minutes, the full TLBG and DOWN Arrow will flash until
you descend below the Required Stop Depth.
After the Audible stops (10 seconds), the TLBG will stop flashing.
The Down Arrow will continue to flash until you descend below
the required Decompression Stop Depth.
> Delayed Violation #1 is a continuation of a Conditional
Violation.
DELAYED VIOLATION # 2 (Fig. 83)
The CompuMask cannot calculate Decompression times for Stop
Depths much greater than 60 FT (18 M) and offers no indication
of how much time spent underwater would result in the need for
a greater Stop Depth.
If the Decompression obligation requires a Ceiling Stop Depth
between 60 FT (18 M) and 70 FT (21 M), the Audible will sound
(10 seconds) and the TLBG and UP Arrow will flash.
Fig. 82 - DELAYED
VIOLATION # 1
Fig. 83 - DELAYED
VIOLATION # 2