![Aeris CompuMask Operating Manual Download Page 15](http://html.mh-extra.com/html/aeris/compumask/compumask_operating-manual_2861741015.webp)
15
Situations that will activate the NOR/GAU 10 second Alarm include -
Air Time Remaining (ATR) at 5 minutes, then again at 0 minutes.
ATR becomes less than No Deco and O2 Time Remaining for 1 minute.
Turn Pressure at the Set Point selected.
End Pressure at the Set Point selected.
Descent deeper than the Max Depth Set Point selected.
Dive Time Remaining at the Set Point selected.
Elapsed Dive Time at the Set Point selected.
PO2 increases to the Set Point selected.
High O2 of 300 OTU (single or daily exposure).
Tissue Loading Bar Graph at the segment Set Point selected.
NOR/GAU Ascent Rate exceeds 60 FPM (18 MPM) when deeper than 60 FT (18 M),
or 30 FPM (9 MPM) at 60 FT (18 M) and shallower.
Loss of the active Transmitter Link signal for more than 15 seconds during a dive.
Entry into Decompression Mode (Deco).
Conditional Violation (above a required Deco Stop Depth for less than 5 minutes).
Delayed Violation (above a required Deco Stop Depth for more than 5 minutes).
Delayed Violation (a Deco Stop Depth greater than 60 FT/18 M is required).
Delayed Violation (Maximum Operating Depth of 330 FT/99.9 M is exceeded).
A single short beep (which cannot be disabled) is emitted for the following -
Upon completion of a Hot Swap battery change.
Change from Delayed to Full Violation 5 minutes after the dive.
Summary of Contents for CompuMask
Page 1: ......
Page 78: ...78 This page intentionally left blank ...
Page 96: ...96 This page intentionally left blank ...
Page 122: ...122 This page intentionally left blank ...
Page 149: ......