![ABB OmniCore V250XT Product Manual Download Page 98](http://html.mh-extra.com/html/abb/omnicore-v250xt/omnicore-v250xt_product-manual_5109098.webp)
Note
The cable shall be protected from external EM disturbance, suggested to use
separate multicore cables.
Note
All external safety devices must be connected to the Customer Safety Interface.
Note
The ESOUT pins reflect the emergency status of the controller.
ESOUT can be decoupled from ES input to avoid dead-lock in an emergency
stop chain, when using RobotWare 7.6 or later. On controllers running RobotWare
releases prior to 7.6, it is not recommended to directly connect ESOUT pins to
the ES pins on another OmniCore controller. See
Although the Motors On function is available on the FlexPendant, an interface is
provided in X15 for an optional Motors On push button and an indication lamp.
K2.X15
Customer provided
device
24V_MON
MON_PB
24V_MON
MON_LAMP
Lamp
Push bu!on
2
1
4
3
xx1900000598
Connector X19
Description
Customer IO power supply
Connection
Weidmüller BCF 3.81/08/180F
Type
BCF 3.81/08/180F SN BK BX 8 Pins
3HAC064739-001
Article number
Continues on next page
98
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.8 Descriptions for connectors
Continued
Summary of Contents for OmniCore V250XT
Page 1: ...ROBOTICS Product manual OmniCore V250XT ...
Page 34: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 410: ...This page is intentionally left blank ...
Page 418: ...This page is intentionally left blank ...
Page 454: ......
Page 455: ......