As an exception to the reserved ranges mentioned in section
, the Ability Network is allowed to configure IP addresses within the
reserved range 192.168.126.0 - 255, but not within 192.168.125.0 - 255 or
192.168.127.0 - 255.
For security reasons, only outbound access on port 53 DNS and 443 HTTPS are
allowed. The inbound access is blocked by an internal firewall and cannot be
unblocked.
Note
For more information about connecting the Ability port to the internet, see
Application manual - Controller software OmniCore
.
Public Network
The Public Network interface is typically connected to the factory network with a
public IP address provided by the network administrator. The Public Network
segment can be used for:
•
Connecting a PC running RobotStudio. For more information see
Operating
manual - RobotStudio
.
•
Mounting FTP or NFS disks from the controller.
•
Running Industrial Ethernet protocols.
Most protocols are disabled by default in the controller firewall. See
for information about how to enable these protocols.
The Public Network can be configured with a fixed IP address, or as a DHCP client,
either in RobotStudio or from the FlexPendant:
•
Defining network settings in RobotStudio:
1 In the
Configuration
browser, right-click the controller and select
Properties\Network Settings
and then
Public Network
.
Continues on next page
88
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.7 Ethernet networks on OmniCore
Continued
Summary of Contents for OmniCore V250XT
Page 1: ...ROBOTICS Product manual OmniCore V250XT ...
Page 34: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 410: ...This page is intentionally left blank ...
Page 418: ...This page is intentionally left blank ...
Page 454: ......
Page 455: ......