Note/Illustration
Action
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
3
xx2100000318
.
Verify that the LED
DC-BUS High
is not
lit.
4
Removing the drive unit
Note/Illustration
Action
Disconnect:
•
T4.X7 -X12, T4.X15
•
T4.X17 - A1.X2
•
T4.X13 - A1.X11
•
T4.X5 - A1.X4
•
T4.X3 - A1.X12
•
T4.X1 - A1.X5
1
Lengthened screwdriver
Remove the screws and pull the drive
unit out from the two guiding pins on the
mounting plate.
CAUTION
The weight of the drive unit is 11 kg.
Use protective gloves when lifting this
unit.
2
xx2100000338
CAUTION
The cabling is sensitive to mechanical
damage. Handle it with care to avoid
damage to the cabling or the connector,
avoid any kind of tilt or skew.
Continues on next page