Troubleshooting procedure
The troubleshooting table is supposed to be used as a detailed instruction together
with the troubleshooting flowchart.
Note
Action
Make sure that the power unit is operational.
Make sure the power has been off
for more than 10 seconds.
1
Wait at least 1 min after power-on.
Power on the controller. Check the
MODULE STATUS LED on the
power unit.
If the MODULE STATUS LED is:
•
Off: The power unit is in the power off
state. Proceed with step
•
Red, steady: Internal error. Proceed with
step
.
•
Flashing red (~ 1Hz): Firmware error or
self-test failure. The power unit may be
faulty, see
.
•
Flashing green (~ 1Hz): Internal commu-
nication error or 24V_SYS is missing.
Proceed with step
•
Steady green but DC-BUS High Voltage
LED is off: Proceed with step
Verify that the input to A1.X1 is 380-480V AC.
•
If AC_IN is between 380-480V AC, pro-
ceed with step
.
•
If AC_IN is is abnormal, there is an issue
with A1.X1. Proceed with step
Verify AC_IN.
2
If the connection seems OK, proceed with step
.
Check the connector at A1.X1 (AC
input). Make sure that the power
cables are connected properly at
both ends.
3
If there is a problem with the connection, pro-
ceed with step
If the connection seems OK, proceed with step
.
Replace AC input cable A1.X1.
4
If there is a problem with the connection, check
power source and incoming mains. Make sure
that AC_IN is OK.
Verify that the input to A1.X6 is 25.2 VDC +/-
5%.
•
If the measured voltage is normal and
MODULE STATUS LED is green, pro-
ceed with step
.
•
If the measured voltage is normal and
MODULE STATUS LED is off, the unit
may be faulty, see
•
If the measured voltage is abnormal,
proceed with step
Measure the 24V_TRUNK at con-
nector A1.X6.
5
Continues on next page
386
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
7 Troubleshooting
7.3.4 Troubleshooting the power unit
Continued
Summary of Contents for OmniCore V250XT
Page 1: ...ROBOTICS Product manual OmniCore V250XT ...
Page 34: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 410: ...This page is intentionally left blank ...
Page 418: ...This page is intentionally left blank ...
Page 454: ......
Page 455: ......