Specifications
The following describes the cable requirements for the incoming mains connection
to the OmniCore V250XT controller.
Description
Component
Flexible oil resistant rubber
Cable type
3G x 6 mm
2
or AWG10
Cable area
PE1 and PE2 points on X0 (incoming mains connector).
Protective earth
Included parts
The following parts are included in the delivery.
Quantity
Order number
Part
1
3HAC075871-001
Connector kit
Procedure
Use the following procedure to fit the connectors.
Note/illustration
Action
Cut the cable to desired length.
1
2
1
3
4
4
PE1
3
PE2
1
2
xx2100001258
Description
L1
1
L2
2
L3
3
Not used
4
Protective earth
PE1
Protective earth
PE2
Connect the wires according to the illus-
tration.
2
Tighten the screws to secure the cables.
3
Remove screw and washer on top of
contact and insert the ground cable with
cable lug. Secure with washer and
screws.
4
76
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.4 Fitting the connector for incoming mains
Continued