Value
Parameter
-3% ~ +10%
Voltage tolerance
4 A
Max output current
Note
The 24 V terminal block power supply is isolated from the internal logical circuit
of the controller.
For connection details, see
Circuit diagram - OmniCore V250XT
,
3HAC074000-008
.
Customer cable layout
It is recommended to use multicore cable for the customer connection.
The cables connected by customer to the 24 V terminal block should go through
the cable grommet and fasten on the cabinet.
Note
The diameter of the cables must match the diameter of the grommet.
Incorrect installation will affect the ingress protection.
It is recommended to use
icotek
KT grommet.
104
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.8 Descriptions for connectors
Continued