366 Parameters
Defines the “at setpoint” limits for speed control of the drive.
When the absolute difference between reference (
) and actual speed (
drive is considered to be “at setpoint”. This is indicated by bit
8 of
100.00 rpm
0.00 … 30000.00
rpm
Limit for “at setpoint” indication in speed control.
See par.
Defines the “at setpoint” limits for frequency control of the
drive. When the absolute difference between reference
(
) and actual frequency (
) is smaller than
, the drive is considered to be “at setpoint”. This is
indicated by bit 8 of
.
10.00 Hz
0.00 … 1000.00 Hz Limit for “at setpoint” indication in frequency control.
See par.
No.
Name/Value
Description
Def
/
FbEq16
(rpm)
0 rpm
(rpm)
(rpm)
(rpm)
Drive at setpoint
bit 8 = 1)
(Hz)
0 Hz
(Hz)
(Hz)
(Hz)
Drive at setpoint
bit 8 = 1)