![ABB ACS880-01 Series Firmware Instructions Download Page 107](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621107.webp)
Program features 107
Mechanical brake control
A mechanical brake can be used for holding the motor and driven machinery at zero
speed when the drive is stopped, or not powered. The brake control logic observes
the settings of parameter group
as well as several
external signals, and moves between the states presented in the diagram on page
. The tables below the state diagram detail the states and transitions. The timing
shows an example of a close-open-close sequence.
The mechanical brake control logic operates on a 10 ms time level.
Inputs of the brake control logic
The start command of the drive (bit 5 of
) is the main control
source of the brake control logic. An optional external open/close signal can be
selected by
. The two signals interact as follows:
• Start command = 1
AND
= 0
→
Request brake to
open
• Start command = 0
OR
= 1
→
Request brake to
close
Another external signal – for example, from a higher-level control system – can be
connected via parameter
to prevent the brake from opening.
Other signals that affect the state of the control logic are
• brake status acknowledgment (optional, defined by
• bit 2 of
(indicates whether the drive is ready to follow the
given reference or not),
• bit 6 of
(indicates whether the drive is modulating or
not),
• optional FSO-xx safety functions module.
Outputs of the brake control logic
The mechanical brake is to be controlled by bit 0 of parameter
. This bit should be selected as the source of a relay output (or a digital
input/output in output mode) which is then wired to the brake actuator through a relay.
See the wiring example on page
.
The brake control logic, in various states, will request the drive control logic to hold
the motor, increase the torque, or ramp down the speed. These requests are visible in
parameter
.
Settings
(page
).
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...