![ABB ACS880-01 Series Firmware Instructions Download Page 551](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621551.webp)
Additional parameter data 551
75.50 Kick start enable
-
-
-
75.51 Kick start hold time
0.0...30.0
s
10 = 1s
75.52 Kick start speed reference
40.0...100.0
%
10 = 1s
75.56 Kick start current ref
0.0...300.0
%
10 = 1%
75.57 Kick start current ramp
0.0...1000.0
%/s
10 = 1%/s
75.60 Current pulse start mode
enable
-
-
-
75.61 Current pulse speed reference
4.0...100.0
%
10 = 1%
75.62 Current pulse start current ref
0.0...300.0
%
10 = 1%
75.68 Current pulse nr of cycles
0...30000
-
1 = 1
75.69 Current pulse cycle time
0.0...30000.0
s
10 = 1s
75.81 Pump speed ref in
0.00...600.00
Hz
100 = 1Hz
75.99 Starting routines status
0000h…FFFFh
-
1 = 1
76 ESP automatic control
76.01 Auto mode enable
-
-
-
76.02 Process control sel
-
-
-
76.11
Auto mode start delay
0...30000
s
1 = 1s
76.19 Auto mode motor ramp time
0.0...30000.0
s
10 = 1s
76.29 Invert PI error sign
-
-
-
76.31 Process 1 control feedback src
-
-
-
76.33 Process 1 control set point
0.00...3000000.00
-
100 = 1
76.35 Process 1 max scale
0.00...3000000.00
-
100 = 1
76.38 Process 1 reference change
rate
0.00...100000.00
%/interva
l
100 = 1
%/interval
76.39 Process 1 ref step interval
0.0...30000.0
s
10 = 1s
76.41 Process 1 control P-gain
0.000...100000.000
-
1000 = 1
76.42 Process 1 control I-time
0.0...1000000.0
s
10 = 1s
76.51 Process 2 control feedback src
-
-
-
76.53 Process 2 control set point
0.00...3000000.00
-
100 = 1
76.55 Process 2 max scale
1.00...3000000.00
-
100 =1
76.58 Process 2 reference change
rate
0.00...10000.00
%/interva
l
100 = 1
%/interval
76.59 Process 2 ref step interval
0.0...30000.0
s
10 = 1s
76.61 Process 2 control P-gain
0.000...100000.000
-
1000 = 1
76.62 Process 2 control I-time
0.0...1000000.0
s
10 = 1s
76.80 PI feedback %
-300.00...300.00
%
100 = 1%
76.81 PI setpoint %
-300.00...300.00
%
100 = 1%
76.82 PI error %
-300.00...300.00
%
100 = 1%
76.83 P term
-300.00...300.00
-
100 = 1
76.84 I term
-300.00...300.00
-
100 = 1
76.85 PI output
-300.00...300.00
%
100 = 1%
76.86 Process 1 feedback signal
-30000.00...30000.00
-
100 = 1
No.
Name
Type
Range
Unit
FbEq32
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...