Parameters 361
Determines how the drive reacts upon a mechanical brake
control error.
Note:
is set
to
, acknowledgement status supervision is
disabled altogether and will generate no warnings or faults.
However, the brake open conditions are always supervised.
Fault
The drive trips on a
Mechanical brake closing failed
/
Mechanical brake opening failed
fault if the status of the
acknowledgement does not match the status presumed by
the brake control logic.
The drive trips on a
fault if the brake open conditions cannot be fulfilled
(for example, the required motor starting torque is not
achieved).
0
Warning
The drive generates a
Mechanical brake closing failed
/
Mechanical brake opening failed
warning if the status of
the acknowledgement does not match the status presumed
by the brake control logic.
The drive generates a
warning if the brake open conditions cannot be
fulfilled (for example, the required motor starting torque is not
achieved).
1
Open fault
Upon closing the brake, the drive generates a
Mechanical brake closing failed
warning if the status of the
acknowledgement does not match the status presumed by
the brake control logic.
Upon opening the brake, the drive trips on a
fault if the status of the
acknowledgement does not match the status presumed by
the brake control logic.
The drive trips on a
fault if the brake open conditions cannot be fulfilled
(for example, the required motor starting torque is not
achieved).
2
Defines a close fault delay, ie. time between brake closure
and brake close fault trip.
0.00 s
0.00 … 60.00 s
Brake close fault delay.
100 = 1 s
45
Settings for the energy saving calculators.
See also section
).
Displays the energy saved in GWh compared to direct-on-line
motor connection. This parameter is incremented when
rolls over.
This parameter is read-only (see parameter
).
-
0…65535 GWh
Energy savings in GWh.
1 = 1 GWh
Displays the energy saved in MWh compared to direct-on-line
motor connection. This parameter is incremented when
rolls over.
When this parameter rolls over, parameter
is incremented.
This parameter is read-only (see parameter
).
-
0…999 MWh
Energy savings in MWh.
1 = 1 MWh
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...