Parameters 357
Selects the fault limit for the brake resistor protection based
on the thermal model. See parameter
.
When the limit is exceeded, the drive trips on fault
.
The value is given in percent of the temperature the resistor
reaches when loaded with the power defined by parameter
.
105%
0 … 150%
Brake resistor temperature fault limit.
1 = 1%
Selects the warning limit for the brake resistor protection
based on the thermal model. See parameter
When the limit is exceeded, the drive
generates a
warning.
The value is given in percent of the temperature the resistor
reaches when loaded with the power defined by parameter
.
95%
0 … 150%
Brake resistor temperature warning limit.
1 = 1%
44
Configuration of mechanical brake control.
See also section
(page
Displays the mechanical brake control status word.
This parameter is read-only.
-
0000h…FFFFh
Mechanical brake control status word.
1 = 1
Displays the torque (in percent) at the instant of the previous
brake close command.
This value can be used as a reference for the brake open
torque. See parameters
and
-
-1600.0 … 1600.0% Torque at brake closure.
See par.
Displays the currently active brake open torque. See
parameters
.
This parameter is read-only.
-
-1600.0 … 1600.0% Currently active brake open torque.
See par.
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Information
0
Open command
Close/open command to brake actuator (0 = close, 1 = open).
Connect this bit to desired output.
1
Opening torque
request
1 = Opening torque requested from drive logic
2
Hold stopped
request
1 = Hold requested from drive logic
3
Ramp to stopped
1 = Ramping down to zero speed requested from drive logic
4
Enabled
1 = Brake control is enabled
5
Closed
state
6
Opening
state
7
Open
state
8
Closing
state
9…15
Reserved
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...