152 Parameters
Parameter listing
No.
Name/Value
Description
01
Basic signals for monitoring the drive.
All parameters in this group are read-only unless otherwise
noted.
Measured or estimated motor speed depending on which
type of feedback is used (see parameter
). A filter time constant for this signal can
be defined by parameter
.
-
-30000.00 …
30000.00 rpm
Measured or estimated motor speed.
See par.
Estimated motor speed in rpm. A filter time constant for this
signal can be defined by parameter
-
-30000.00 …
30000.00 rpm
Estimated motor speed.
See par.
Shows the value of
in percent of the
synchronous speed of the motor.
10 = 1%
-1000.00 …
1000.00%
Measured or estimated motor speed.
See par.
Speed of encoder 1 in rpm. A filter time constant for this
signal can be defined by parameter
-
-30000.00 …
30000.00 rpm
Encoder 1 speed.
See par.
Speed of encoder 2 in rpm. A filter time constant for this
signal can be defined by parameter
-
-30000.00 …
30000.00 rpm
Encoder 2 speed.
See par.
Estimated drive output frequency in Hz. A filter time constant
for this signal can be defined by parameter
-
-500.00 … 500.00
Hz
Estimated output frequency.
See par.
Measured (absolute) motor current in A.
-
0.00 … 30000.00 A
Motor current.
See par.
Motor current (drive output current) in percent of the nominal
motor current.
-
0.0 … 1000.0%
Motor current.
1 = 1%
Motor torque in percent of the nominal motor torque. See also
parameter
A filter time constant for this signal can be defined by
parameter
-
-1600.0 … 1600.0% Motor torque.
See par.
Measured DC link voltage.
-
0.00 … 2000.00 V
DC link voltage.
10 = 1 V
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...