532 Additional parameter data
33.52 Value counter 1 function
00b…11b
-
1 = 1
33.53 Value counter 1 source
-
-
1 = 1
33.54 Value counter 1 divider
0.001 … 2147483.000
-
1000 = 1
33.55 Value counter 1 warn message
-
-
1 = 1
33.60 Value counter 2 actual
-2147483008 …
2147483008
-
1 = 1
33.61 Value counter 2 warn limit
-2147483008 …
2147483008
-
1 = 1
33.62 Value counter 2 function
00b…11b
-
1 = 1
33.63 Value counter 2 source
-
-
1 = 1
33.64 Value counter 2 divider
0.001 … 2147483.000
-
1000 = 1
33.65 Value counter 2 warn message
-
-
1 = 1
35 Motor thermal protection
35.01 Motor estimated temperature
-60 … 1000
°C or °F
1 = 1°
35.02 Measured temperature 1
-60 … 1000 °C,
-76 … 1832 °F,
0…5000 ohm
°C, °F or
ohm
1 = 1 unit
35.03 Measured temperature 2
-60 … 1000 °C,
-76 … 1832 °F,
0…5000 ohm
°C, °F or
ohm
1 = 1 unit
35.04 FPTC status word
0000h…FFFFh
-
1 = 1
35.11 Temperature 1 source
0…11
-
1 = 1
35.12 Temperature 1 fault limit
-60 … 1000 °C,
-76 … 1832 °F or
0…5000 ohm
°C, °F or
ohm
1 = 1 unit
35.13 Temperature 1 warning limit
-60 … 1000 °C,
-76 … 1832 °F or
0…5000 ohm
°C, °F or
ohm
1 = 1 unit
35.14 Temperature 1 AI source
-
-
1 = 1
35.21 Temperature 2 source
0…11
-
1 = 1
35.22 Temperature 2 fault limit
-60 … 1000 °C,
-76 … 1832 °F or
0…5000 ohm
°C, °F or
ohm
1 = 1 unit
35.23 Temperature 2 warning limit
-60 … 1000 °C,
-76 … 1832 °F or
0…5000 ohm
°C, °F or
ohm
1 = 1 unit
35.24 Temperature 2 AI source
-
-
1 = 1
35.30 FPTC configuration word
0000h…FFFFh
-
1 = 1
35.50 Motor ambient temperature
-60 … 100 °C or
-76 … 212 °F
°C or °F
1 = 1°
35.51 Motor load curve
50…150
%
1 = 1%
35.52 Zero speed load
50…150
%
1 = 1%
35.53 Break point
1.00 … 500.00
Hz
100 = 1 Hz
No.
Name
Type
Range
Unit
FbEq32
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...