44 ESP program features
5
Drive stops measuring the actual pump-motor speed if Start command
if OFF when parameter
timer is still
counting.
6
Parameter
is set ON, so that when
restart delay time is elapsed, the speed measurement function starts
automatically.
2-3, 7-8,
13-14
The time needed for the Backspin speed observer function to detect
the actual motor speed is defined with parameter
.
7-9
When Backspin speed observer is active, the drive start command will
have no effect until measured speed gets in to the safe-to-restart speed
region defined with parameters
.
9-11
The speed observer function will trigger the speed check timer set in
parameter
when the measured
speed is within the safe-to-restart speed region.
10
If the measured speed is outside safe-to-restart speed region, then the
speed check timer will reset.
11-12
If the measured speed is within the safe-to-restart speed region defined
in parameter
, then the speed
observer function routine is over. The drive stops modulating and
parameter
, bit 8 is set to TRUE.
In case user drive start command is active, then immediately after
speed check time is elapsed the flying start sequence is initiated and
drive takes control over the pump-motor to go over the starting routines
and then accelerate it to the production speed.
12-13
The drive is waiting for the user to initiate the drive start command.
13-14
As soon as the user drive start command is given, the drive repeats
speed measurement routine to ensure that the actual speed is within
the safe-to-restart speed region, then the drive will proceed to the
normal starting routine without any speed check time delay.
If the speed is outside the safe-to-restart speed region, then all the
speed supervision procedure is repeated from point 8.
14-15
The drive gets in to normal production state through the starting
routines.
Control
scenario
Description
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...