86
For example:
G00 X10.5 Y200.5;
Step1. Press function key [MDI], enter MDI mode;
Step2. Press function key [PROG];
Enter “G00 X10.5”;
Step3. Press key [INSERT], “G00 X10.5” is displayed in the interface.
CAUTION
:
1.
If input error is found before press key [INSERT], press the key [CAN] to cancel input one by one
2.
If the system prompts error, when press key [INSERT], enter the correct value again;
3.
If need to modify the input, select the character to be modified, press key [DELETE], input as the above
step. You can also select the characters to be modified, and press key [
ALTER
] to replace the characters with the
correct characters.
4.
Enter Y200.5, press key [INSERT], “Y200.5”is displayed in the interface.
5.
Press key [CYCLE START], run the program.
CAUTION:
The system will automatically clear program buffer, when the MDI program is finished.
Fig.6-1 MDI Program Interface
6.1.3 DNC Operation
When run large program, usually select DNC operation mode. Steps are as follows:
1.
Press function key [DNC], enter DNC operation mode;
2.
Select [PROG] interface;
3.
Set serial communication parameters;
4.
Connect the system and PC with serial communication wire;
5.
Transfer program with transfer software
6.
Press key [CYCLE START] run the program, when program appears in [PROG] interface.
6.2 Start of Automatically Operation
Step 1: Select [EDIT] manner;
Step 2: Select program, the operation as follows: