83
4.1 FEED AXIS CONTROL
In manual operation mode, the axis can run at manual feed speed or manual rapid moving speed.
4.1.1 Manual Feed
In manual operation mode, press key [X] ,[Y] ,[Z] select axis, then press[+],[-] , the corresponding axis
begins to move. The moving speed can be adjusted by changing the feed rate, motion stops when release key.
CAUTION:
1. The system also supports multi axis manual movement, namely manual linkage;
2. The axis manual feed speed is determined by parameters NO. 1063-1068 (motor manual feed speed).
4.1.2 Manual Rapid Traverse
Press feed key [RAPID], indicator lamp is on, Enter the manual rapid traverse, and press axis direction key,
then axis move as rapid traverse speed.
4.1.3 Manual Feed and Manual Rapid Traverse Rate Select
In manual feed mode, manual feed rate can be changed by press function key [feed increase] and [feed
reduce].By default, there are totally16 feed rates for the user to choose: 10%~150%. The maximum feed rate is
determined by parameter NO. 1177.(maximum input feed rate).
When manual rapid traverse, manual rapid traverse rate can be changed by press function key [X1], [X10],
[X100]. By default, there are totally 4 rapid rates for the user to choose: F0, 25%, 50%, 100%. Speed of F0 is
determined by parameters NO.1266 and 1268 (motor rapid traverse F0 speed).
CAUTION
:
1.
Manual feed rate, rapid traverse rate can be viewed in position interface;
2.
Selection of rapid traverse rate has effect on the following move speed:
1)
Rapid traverse by G00;
2)
Rapid traverse during a canned cycle;
3)
Rapid traverse when G28 is on.
4)
Manual rapid traverse.
3. Feed rate keys are disabled, when axis is moving.
4.2 Spindle Control
Specify spindle speed in the MDI mode, spindle clockwise, CCW when press function key [SPDL CW],
[SPDL CCW] in manual/handle/MDI mode.
In JOG/handle/MDI mode, spindle stops rotating, when function key [SPDL SP] is pressed.
Spindle specified position stop: In manual mode, stop the spindle in specified position, convent the
operations such as tool retract.
CAUTION:
1.
Each spindle’s maximum speed is determined by parameters NO.0014.( Spindle speed limit);
2.
Reset, emergency stop buttons can make the spindle stop
3.
When spindle is CW rotating, it is prohibited to press spindle CCW key directly. Spindle should stop
firstly, and then CCW rotates. Similarly, Spindle should stop firstly, from spindle CCW rotation to CW
rotation.
4.3 Other Manual Operation
4.3.1 Coolant Control
Press function key [COOLANT], control coolant on or off. Coolant is off by default when system starts up.