126
reference 1
:
valid for beginning to end
1244
1
Software limitation of motor 2 0
:
valid after returning
reference 1
:
valid for beginning to end
1245
1
Software limitation of motor 3 0
:
valid after returning
reference 1
:
valid for beginning to end
1246
1
Software limitation of motor 4 0
:
valid after returning
reference 1
:
valid for beginning to end
1247
1
Software limitation of motor 5 0
:
valid after returning
reference 1
:
valid for beginning to end
1248
1
Software limitation of motor 6 0
:
valid after returning
reference 1
:
valid for beginning to end
Feed shaft
parameter Z
1387
1
Machine coordinate after power on of motor 1 0
:
reset 1
:
not reset
1388
1
Machine coordinate after power on of motor 2 0
:
reset 1
:
not reset
1389
1
Machine coordinate after power on of motor 3 0
:
reset 1
:
not reset
1390
1
Machine coordinate after power on of motor 4 0
:
reset 1
:
not reset
1391
1
Machine coordinate after power on of motor 5 0
:
reset 1
:
not reset
1392
1
Machine coordinate after power on of motor 6 0
:
reset 1
:
not reset
1171
6000.0000
The hand wheel moving speed upper limit value of motor 1
1172
6000.0000
The hand wheel moving speed upper limit value of motor 2
1173
6000.0000
The hand wheel moving speed upper limit value of motor 3
1174
6000.0000
The hand wheel moving speed upper limit value of motor 4
1175
6000.0000
The hand wheel moving speed upper limit value of motor 5
1176
6000.0000
The hand wheel moving speed upper limit value of motor 6
1180
0.0000
The cumulative limit of hand wheel of motor 1
(
mm
)
1181
0.0000
The cumulative limit of hand wheel of motor 2
(
mm
)
1182
0.0000
The cumulative limit of hand wheel of motor 3
(
mm
)
1183
0.0000
The cumulative limit of hand wheel of motor 4
(
mm
)