78
Fig. 3-18 Pitch error compensation screen
3.14.2 Pitch Error Compensation Setting
1.
Position the corresponding modification items according to procedures 3.11.1;
2.
Enter the modified value
,
press soft key [INPUT]
,
the data/time is set and displayed;
3.
Press [+INPUT] to add modification value to the current value.
NOTE:
1.
Pitch error compensation interval of each feed shaft is set by NO.1126, NO.1131 parameters.
2.
Compensation numbers correspond to pitch error compensation origin points of each feed shaft and
farthest points in the positive and negative direction are set by NO.1135-NO.1158 parameters.
3.15 Ladder Diagram Display Screen
PLC signal state can be seen on the ladder diagram display screen.
1.
Press function key [SYSTEM]
;
3.
Press soft key[LAD],then the ladder diagram screen appears;
4.
Enter the PLC address then press function key [SRH] to search.
Example:
Type R7.0 in and press function key [SRH] to find R7.0 address.