73
3)
No.1 knife does not move, then return to the position coordinates interface, and clear Z relative
coordinates.
4)
Change No.2 tool to align again and press C input at the tool compensation position of the No.2 tool.
NOTE
:
The system can modify the tool compensation value only when in the stop state. After input the current tool
information, the corresponding wear will be deleted.
3.8 Coordinate System Display
Press function button[
OFF/SET
]→[
COORD
] to enter the Coordinate System setting interface ,the contents
of the interface as shown below:
Fig.3-13
Coordinate System Interface
In the workpiece coordinate system setting interface can do the following operation:
1.
Search: Input after 54-59 and run this function can quickly locate to the corresponding workpiece
coordinate system.
2.
Measure: After input X20 and complete measurement, the system of workpiece coordinate system in the
current X value is set to meet the current value of the absolute coordinates of 20.
3.
X axis value half: The first time to perform this function will capture the first point position, then move
to another point, this function will be performed again to find the midpoint of the X axis.
4.
Y axis value half: ditto
5.
+input:+input: add the value of the location of the cursor with the values in the input box
6.
Input: set the value of the position of cursor to the value of the input box, the shortcut key is [INPUT].
3.9 Setting Screen Display
1.
press function button [OFF/SET];
2.
Press soft button [SET]→ [PARAM],the screen display parameters can be set.
3.
Press the direction key [←], move the cursor to the changing project.