Programming
Technical
Manual:
Smartstart
®
6000
IMI0042
rev
K
Page
31
An
optional
‘Start’
function
is
also
selectable
as
a
digital
input.
This
is
a
latching
input,
which
is
unlatched
by
a
stop
control
input,
deactivating
the
enable
input
or
a
trip.
Level
Sense:
The
default
setting
when
using
the
enable
input
to
run
the
soft
starter.
For
‘power
‐
up’
start
with
line
supply
to
function,
‘level
sense’
must
be
selected.
Also
used
for
2
wire
run/stop
control
using
the
digital
input
‘Start’
and
enable
input.
(may
be
used
in
conjunction
with
the
‘stop’
or
‘coast’
input).The
start
signal
must
be
present
until
motor
commences
start.
Edge
Sense:
Will
only
start
with
an
edge
trigger.
This
is
the
recommended
setting
for
3
wire
start/stop
control.
May
also
be
used
to
prevent
an
unexpected
start,
if
‘stop/coast’
is
restored
and
enable/start
input
signal
remains
active.
Refer
to
page
14
more
wiring
configuration.
Refer
to
pages
26
‐
27
for
selection
of
digital
inputs
and
also
page
34
for
description
of
the
digital
input
variables..
A61
Try
Tiny
Motor
Allows
a
test
of
the
starter
using
a
small
test
motor
or
motor
smaller
than
the
starter
is
rated.
Range:
Enable/Disable
Default:
Disable
To
save
changes
To
exit
without
saving
The
Smartstart
®
6000
will
trip
on
motor
loss
if
motor
current
falls
below
15%
of
the
entered
FLC.
This
creates
a
problem
for
workshop
testing
or
fault
finding.
If
‘Try
Tiny
Motor’
is
enabled
a
start
is
allowed
which
ignores
this
protection.
When
the
control
supply
is
removed
this
automatically
resets
to
’disabled’.
Below
are
the
menu
parameters
that
may
require
adjustment
to
allow
communication
to
take
place
with
other
devices.
The
Communication
setup
must
be
completed
and
checked
before
communications
can
begin.
For
more
comprehensive
instructions
and
mapping
details
refer
to
the
corresponding
‘SS6000
Networking
guide’.
N01
Net
protocol
Select/enable
the
desired
Communications
protocol.
Range:
Disable;
Modbus
RS485:
Modbus
TCP
Default:
Disable
To
save
changes
To
exit
without
saving
N02
Net
Control
(RS485
&
Ethernet)
Select
desired
operation
on
a
network
control
timeout.
Range:
Disabled;
Stop
On
T/O;
Trip
On
T/O
Default:
Disable
To
save
changes
To
exit
without
saving
N03
Net
Timeout
(RS485
&
Ethernet)
Adjust
for
the
time
delay
for
the
timeout
function.
Range:
0.1
–
60secs
Default:
2.0sec
To
save
changes
To
exit
without
saving
N04
Net
Config
Set
for
desired
operation
for
communications
.
Range:
All
settings;
disabled,
display
only;
Adj
ramps;
Inputs/Outputs;
Restart
Default:
All
Settings
To
save
changes
To
exit
without
saving
N10
RS485
Addr
(RS485
only)
Adjust
to
the
desired
network
address
value
for
the
soft
starter.
Each
device
on
the
bus
must
have
a
unique
address.
Range:
0
‐
247
Default:
0
To
save
changes
To
exit
without
saving
Setup Menu