Programming
Technical
Manual:
Smartstart
®
6000
IMI0042
rev
K
Page
26
P61
Under
torque
Alarm:
Provide
protection
against
under
‐
torque.
This
protection
is
not
active
during
the
accel
&
decel
period.
Range:
off;
trip;
warn
Default:
off
To
save
changes
To
exit
without
saving
‘Trip’:
The
soft
starter
trips,
stops
the
motor
and
indicates
an
‘Under
Torque
trip’.
The
Trip
relay
will
change
state
if
selected.
‘Warn’:
The
soft
starter
does
not
trip
or
stop
the
motor.
See
D05
&
D06
for
more
information
regarding
warning
alarms.
P62
Under
Torque
Level:
Adjust
to
the
desired
trip
threshold,
as
a
percentage
of
nominal
torque.
Range:
10
–
100%
Default:
10%
To
save
changes
To
exit
without
saving
P63
Under
Torque
Delay:
Adjust
to
set
the
time
period
that
the
torque
must
fall
below
the
threshold
before
a
trip
occurs.
Range:
1
‐
90
seconds
Default:
10
s
To
save
changes
To
exit
without
saving
P70
Over
Torque
(Electronic
Shear
Pin):
Electronic
Shear
Pin
or
protection
against
over
torque.
This
protection
is
not
active
during
the
accel
&
decel
period.
To
enter
submenu
to
modify
To
exit
sub
menu
P71
Over
Torque
Alarm:
Provide
protection
against
excess
torque.
This
protection
is
not
active
during
the
accel
&
decel
period.
Range:
off;
trip;
warn
Default:
off
To
save
changes
To
exit
without
saving
‘Trip’:
The
soft
starter
trips,
stops
the
motor
and
indicates
an
‘Over
Torque
trip’.
The
Trip
relay
will
change
state
if
selected.
‘Warn’:
The
soft
starter
does
not
trip
or
stop
the
motor.
See
D05
&
D06
for
more
information
regarding
warning
alarms.
P72
Over
Torque
Level:
Adjust
to
the
desired
trip
threshold,
as
a
percentage
of
nominal
torque.
Range:
80
–
250%
Default:
100%
To
save
changes
To
exit
without
saving
P73
Over
Torque
Delay:
Adjust
to
set
the
time
period
that
the
torque
must
exceed
the
threshold
before
a
trip
occurs.
Range:
0
‐
30
seconds
Default:
10
s
To
save
changes
To
exit
without
saving
R01
Manual
Reset
Activate
or
de
‐
activate
the
manual
reset
ie.
The
reset
on
the
local
console.
Range:
Enable;
Disable
Default:
Enable
To
save
changes
To
exit
without
saving
R02
Power
Reset
Activate
or
de
‐
activate
reset
on
removal
of
control
supply.
Range:
Enable;
Disable
Default:
Enable
To
save
changes
To
exit
without
saving
Status
Level
Delay
P70 Over Torque
Trip 100% 5s
Setup Menu
5 Reset / Restarts
Содержание SMARTSTART 6000
Страница 1: ...ZENER VARIDRIVE SOLUTIONS ZENER SMARTSTART 6000 Soft Starter Instruction Manual...
Страница 2: ......
Страница 49: ...Appendix B Application Diagrams Technical Manual Smartstart 6000 IMI0042 rev K Page 46 General Purpose...
Страница 51: ...Appendix B Application Diagrams Technical Manual Smartstart 6000 IMI0042 rev K Page 48 Irrigation Pump...