Programming
Technical
Manual:
Smartstart
®
6000
IMI0042
rev
K
Page
17
Operating Status Indication
‘Off’
:
The
Smartstart
®
6000
has
control
power
applied
but
not
enabled
and
no
line
supply.
‘Standby’
:
The
Smartstart
®
6000
has
been
enabled
to
start
and
the
run
relay
energized
to
bring
in
the
line
contactor
(if
installed).
The
Smartstart
®
6000
will
initiate
a
start
immediately
3
phase
supply
is
applied.
‘Ready’
:
Line
supply
on
but
nor
enabled.
‘ACCEL
##%’
:
The
Smartstart
®
6000
is
accelerating
the
motor.
Ramp
time
completed
(%)
&
Motor
Current
(A)
displayed.
‘At
Speed
##%’
:
The
motor
is
at
full
speed,
the
accel
time
period
may
not
be
complete.
Ramp
time
completed
(%)
&
Motor
Current
(A)
is
displayed.
‘Run
Bypass
or
Run
Cont.’
:
The
ramp
time
is
complete
and
the
bypass
contactor
operated
or
SCR’s
are
in
full
conduction.
Motor
Current
(A)
is
displayed.
‘DECEL
##%’
:
The
Smartstart
®
6000
is
decelerating
the
motor.
Ramp
time
completed
(%)
&
Motor
Current
(A)
displayed
‘Start
Req’
:
Enabled,
but
start
delayed/postponed
due
to
cooling
or
start
timer
delay.
‘Kick
Start’:
Kick
start
is
active.
‘Motor
Off’:
Brief
message
as
motor
defluxes
or
Pending
motor
loss
trip.
‘Tripped’:
System
has
tripped.
(Not
seen
in
Auto
retart)
‘Cooling’:
Starter
too
hot
to
start
or
during
“Minimum
off
time”.
‘Shut
down’:
PSU
under
voltage
detected
(SMARTSTART
shutting
down).
‘Brownout’:
Sustained
PSU
under
voltage
condition
(supply
problem/fault).
‘AR
Pending’:
System
tripped
but
waiting
for
auto
restart.
‘AR
Lockout’:
Final
trip
after
all
AR
attempts
exhausted.
Warnings, Alarms and Messages:
The
Smartstart
®
6000
has
been
designed
to
provide
the
user
with
a
comprehensive
display
of
its
operating
status.
Messages
in
plain
English
are
flashed
across
the
screen
(if
enabled)
to
alert
the
user
of
its
current
status,
any
warnings,
trips
or
pending
actions.
The
code
will
have
a
prefix
of
T
(trip),
W
(Warning)
or
I
(Interlock).
Example
1:
If
auto
restart
is
selected
it
will
flash:
‘
AR
PENDING’,
the
number
of
restarts
and
time
before
a
restart.
Example
2:
If
the
motor
or
starter
has
reached
a
thermal
state
where
cannot
restart
it
will
flash
:
‘PENDING,
I30
MTR
OVERLOAD’
‘FLASH
ALERTS’
(Top
Line
of
Display)
The
Smartstart
®
6000
can
be
configured
to
Flash
Warning
&
Alarm
messages
irrespective
of
the
DASHBOARD
screen
currently
active.
See
‘D05
Warning
alarms’
on
page
21.
These
alerts
include:
PENDING
WARNING
TRIPPED
OVERRIDE
AR
#12
in
1234s
AR#12
Anytime
LOCKOUT
Refer
to
table
4
on
page
34
for
explanation
of
each.
‘ALARMS
and
interlock
Messages
The
Smartstart
®
6000
can
be
configured
to
Display
the
Trip
code
and
Description
over
the
bar
graph
on
the
default
screen.
Interlock
messages
can
also
be
displayed.
See
‘D06
Alm
over
bar’
on
page
21.
Interlock
Messages
When
this
feature
is
enabled
(ie.
D06
‐
‘All
Alarms’)
interlock
messages
are
displayed
on
the
2
nd
line.
Refer
to
‘D06
Warning
Alarms’
for
more
information).
Interlock
messages
have
an
‘
I
’
prefix.
Eg.
‘I70 Enable OFF’
.
These
messages
provide
more
information
about
the
current
status
of
the
starter
and
provide
diagnostics
to
why
the
motor
may
not
be
operating.
Refer
to
page
35
&
36
for
explanation
of
these
messages.
ACCEL
50 %
250A
300%
Current
status
%
of
Accel
or
Decel
time
Actual
Current
Current
as
%
of
motor
FLC.
(Programmable)
Bar
Graph
displaying
current%