Programming
Technical
Manual:
Smartstart
®
6000
IMI0042
rev
K
Page
30
To
save
changes
To
exit
without
saving
A31
Decel
Profile
Select
the
type
of
deceleration
profile
to
match
the
type
of
load
or
application.
Range:
Linear;
Squared
Default:
Linear
To
save
changes
To
exit
without
saving
A32
Decel
Control
Select
the
type
of
deceleration
control
to
suit
the
load
or
application.
Torque
control
will
provide
greater
control
over
the
deceleration
/
stopping
of
a
motor
under
load.
Range:
Torque;
Voltage
Default:
Torque
To
save
changes
To
exit
without
saving
A41
Motor
Mtr
OL
Reset
Enter
the
level
for
the
Motor
over
load
protection
to
allow
a
reset.
Range:
10
–
100%
Default:
75%
To
save
changes
To
exit
without
saving
A42
Str
OT
Reset
Enter
the
level
for
the
Starter
over
temperature
protection
to
allow
a
reset.
Range:
40
–
90°
C
Default:
60°
C
To
save
changes
To
exit
without
saving
A43
Warning
Level
Set
the
threshold
level
for
warning
alarms
with
protection
based
on
level
only.
Eg.
Thermal
trips
such
as
Motor
Overload.
Enter
as
a
%.
Range:
50
‐
100%
Default:
90%
To
save
changes
To
exit
without
saving
A44
Warning
Delay
Set
the
warning
threshold
for
protection
based
on
a
time
function.
Eg.
Overcurrent.
Enter
as
a
%
of
the
trip
delay
time.
Range:
25
‐
100%
Default:
50%
To
save
changes
To
exit
without
saving
Notes:
1)
If
the
soft
starter
is
configured
to
display
warning
alarms(see
D05
&
D06)
this
sets
the
threshold
point
which
a
warning
alert
is
displayed.
The
screen
will
display:
WARNING
followed
by
a
code
and
description.
Eg.
W33
MTR
OVERCURR
2)
If
a
relay
is
configured
for
‘Warning’
then
the
relay
will
change
state.
A51
Motor
Stator
Enter
Details
of
the
Motor
Stator.
Range:
1.5
–
5.0%
Default:
3.0%
To
save
changes
To
exit
without
saving
A52
Min
off
time
Adjust
this
parameter
to
provide
a
minimum
off
time
before
a
start
is
permitted.
This
will
limit
the
amount
of
starts
per
hour
and
allow
the
soft
starter
(or
Motor)
to
cool
before
a
restart.
Range:
0
–
600mins
Default:
0.0
To
save
changes
To
exit
without
saving
**
The
motor
may
restart
after
time
lapsed
if
enabled**
A53
Start
logic
This
parameter
sets
the
operation
of
a
start
signal,
whether
it
senses
level
or
an
edge
of
a
start
signal.
Range:
Edge
sense
;
Level
sense
Default:
Level
sense
To
save
changes
To
exit
without
saving
The
enable
input
is
generally
used
as
the
level
sensed
run
input
for
the
soft
starter.