10.4 Improved Functions
10-15
10
Upgraded V
ersions
10.4 Improved Functions
10.4.1 Moment of Inertia Ratio Setting Range
A load with moment of inertia ratio (Pn103) more than the existing maximum value 10,000% may be connected
to a direct-drive motor. Accordingly, the upper limit of Pn103 is increased to 20,000%.
* Used when the software version is 32 or later.
10.4.2 Adaptation to Single-turn Data Absolute Encoder
A single-turn data absolute encoder is mounted to SGMCS direct-drive servomotor as standard.
The machine configuration with a SGMCS servomotor does not require harmonic gear, etc. so that the servomo-
tor can be connected directly to a load. Therefore, for its absolute value detecting system, the load-end absolute
value can be obtained by measuring only the angle of motor shaft.
In this case, the encoder multi-turn data is not required and no backup battery is required.
(With a single-turn data absolute encoder, the multi-turn data is always set to “0.”)
• Single-turn data absolute encoder model: UTSB
-B
Confirm the single-turn absolute encoder model in Motor Models Display (Fn011) on the digital operator or
panel operator:
• Encoder Model/Encoder Resolution Display
After executing Fn011, the following screen will appear.
Pn103
Moment of Inertia Ratio
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 to 10000
(0 to 20000) *
1 %
0
Immediately
Speed
Position
Torque
Encoder Resolution
Code
13
16
17
20
13 bits
16 bits
17 bits
20 bits
Specification
Encoder Model
Code
00
01
02
Incremental encoder
Multiturn data absolute encoder
Single-turn data absolute encoder