5.8 Peripheral Devices
5-61
5
Specifications and Dimensional Drawings of Cables and Peripheral Devices
5.8.3 Cables for Analog Monitor
(1) Cable Type: JZSP-CA01 (DE9404559)
Connect the specified cables to CN5 connector for monitoring the analog monitor signals. For details, refer to
9.5 Analog Monitor
.
Note: Specify the cable type either JZSP-CA01 or DE9404559 when ordering the cable for analog monitor.
(2) Dimensional Drawing
* Manufactured by Hirose Electric Corporation.
(3) Specifications
Note: The above monitoring items are the factory settings. The monitoring items can be changed by setting the
parameter Pn003. Refer to
9.5 Analog Monitor
.
CN5
Cable for Analog Monitor
CHARGE
MODE/SET
DATA/
POWER
With the front cover open
3
4
1
2
Socket: DF11-4DS-2C
∗
Connector: DF11-2428SCF
∗
1000
ޓ
mm
-0
+20
White
Red
Black
Black
Viewed from the cable
Pin No.
Cable Color
Signal
Monitoring Item
1
Red
Analog Monitor 2
Motor speed: 1V/1000 min
-1
2
White
Analog Monitor 1
Torque reference: 1V/100% rated torque
3 and 4
Black (2 cables) GND (0 V)
−
Содержание Sigma-II Series