12 Appendix
12.3.2 List of Parameters
12-34
* 1. Used only when the software version is 32 or later.
* 2. The factory setting is 0001 for the models with 5 kW or more.
* 3. The factory setting is 1500 for the models with 5 kW or more.
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Reference
Section
Pn304
JOG Speed
0 to 10000
1 min
-1
500
Immedi-
ately
8.1.1
Pn305
Soft Start Acceleration Time
0 to 10000
1 ms
0
Immedi-
ately
8.5.4
Pn306
Soft Start Deceleration Time
0 to 10000
1 ms
0
Immedi-
ately
8.5.4
Pn307
Speed Reference Filter Time Constant
0 to 65535
0.01 ms
40
Immedi-
ately
8.5.5
Pn308
Speed Feedback Filter Time Constant
0 to 65535
0.01 ms
0
Immedi-
ately
9.4.7
Pn309
Reserved (Do not change)
*1
0 to 500
1 min
-1
60
Immedi-
ately
−
Pn400
Torque Reference Input Gain
10 to 100
0.1 V/rated
torque
30 V
Immedi-
ately
8.7.1
8.9.3
8.9.4
9.4.2
Pn401
Torque Reference Filter Time Constant
0 to 65535
0.01 ms
100
Immedi-
ately
9.4.10
Pn402
Forward Torque Limit
0 to 800
1%
800
Immedi-
ately
8.9.1
Pn403
Reverse Torque Limit
0 to 800
1%
800
Immedi-
ately
8.9.1
Pn404
Forward External Torque Limit
0 to 800
1%
100
Immedi-
ately
8.9.2
8.9.4
Pn405
Reverse External Torque Limit
0 to 800
1%
100
Immedi-
ately
8.9.2
8.9.4
Pn406
Emergency Stop Torque
0 to 800
1%
800
Immedi-
ately
8.3.3
Pn407
Speed Limit during Torque Control
0 to 10000
1 min
-1
10000
Immedi-
ately
8.7.4
Pn408
Torque Function Switches
*1
0000 to 0101
−
0000
*2
Immedi-
ately
9.4.10
Pn409
First Stage Notch Filter Frequency
50 to 2000
1 Hz
2000
*3
Immedi-
ately
9.4.10
0
1
First notch filter disabled.
Uses first notch filter.
Notch Filter Selection
(Refer to "9.4.10 Torque Reference Filter.")
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Reserved (Do not change)
Reserved (Do not change)
0
1
Second notch filter disabled.
Uses second notch filter.
Notch Filter Function 2
∗
1
(Refer to "10.3.4 Second Stage Notch Filter and Changeable Q Value.")
Содержание Sigma-II Series
Страница 384: ...8 3 8 Operation...