11 Inspection, Maintenance, and Troubleshooting
11.2.1 Servomotor Inspection
11-18
11.2 Inspection and Maintenance
11.2.1 Servomotor Inspection
The AC servomotors are brushless. Simple, daily inspection is sufficient. The inspection and maintenance fre-
quencies in the table are only guidelines. Increase or decrease the frequency to suit the operating conditions and
environment.
During inspection and maintenance, do not disassemble the servomotor. If disassembly of the servomotor is
required, contact your Yaskawa representative.
* Measure across the servomotor FG and the phase-U, phase-V, or phase-W power line.
11.2.2 SERVOPACK Inspection
For inspection and maintenance of the SERVOPACK, follow the inspection procedures in the following table
at least once every year. Other routine inspections are not required.
Table 11.6 Servomotor Inspections
Item
Frequency
Procedure
Comments
Vibration and Noise
Daily
Touch and listen.
Levels higher than normal?
Exterior
According to degree
of contamination
Clean with cloth or compressed
air.
−
Insulation Resistance
Measurement
At least once a year
Disconnect SERVOPACK and
test insulation resistance at 500 V.
Must exceed 10 M
Ω
.
∗
Contact your Yaskawa repre-
sentative if the insulation
resistance is below 10 M
Ω
.
Replacing Oil Seal
At least once every
5000 hours
Contact your Yaskawa represen-
tative.
Applies only to servomotors
with oil seals.
Overhaul
At least once every
20000 hours or 5
years
Contact your Yaskawa represen-
tative.
−
IMPORTANT
Table 11.7 SERVOPACK Inspections
Item
Frequency
Procedure
Comments
Check the
Appearance
At least once a year
Check for dust, dirt, and oil
on the surfaces.
Clean with compressed
air.
Loose Screws
Check for loose terminal
block and connector
screws.
Tighten any loose screws.