5 Specifications and Dimensional Drawings of Cables and Peripheral Devices
5.8.16 Encoder Signal Converter Unit
5-82
5.8.16 Encoder Signal Converter Unit
The encoder signal converter unit (the trade name “Receiver Unit”) converts encoder signal output from the line
driver to open-collector or voltage-pulse output.
A socket model 11PFA is required to use a Receiver Unit.
(1) Model: LRX-01 / A
Contact Yaskawa Controls Co., Ltd.
(2) Specifications
(3) Dimensional Drawings
The socket is optional.
Specifications
Receiver Unit
LRX-01/A1
LRX-01/A2
LRX-01/A3
LRX-01/A4
Power Supply
12 VDC
±
10 %, 100 mA
5 VDC
±
5 %, 100 mA
Input Signals
Balanced line driver input (RS-422)
Output Signals
Voltage pulse
output
Open collector
output
Voltage pulse
output
Open collector
output
Input Signal
Level
Differential voltage
≥
0.3 V, built-in terminator 100
Ω
Output Signal
Level
H: 10 V min.
(1 mA)
L: 0.5 V max.
(30 mA)
L: 0.5 V min.
(30 mA)
Withstand volt-
age: 50 V
H: 3 V min.
(1 mA)
L: 0.5 V max.
(30 mA)
L: 0.5 V min.
(30 mA)
Withstand volt-
age: 50 V
Surrounding Air
Temperature
0 to + 60
°
C
IC Used
Receiver IC: AM26LS32C or the equivalent
Response
Frequency
100 kHz
YASKAWA
RS-422
5
33.5 max.
18 max.
35.4
4
4
7.8
11-M3.5
×
7
SEMS screws
51 max.
40
±
0.2
81 max.
2
×φ
4.5
holes
50
80
35.4
129
100
Socket
Receiver unit
29
Receiver unit and socket
Socket Type 11PFA
Units: mm
Содержание Sigma-II Series