4.1 SERVOPACK Ratings and Specifications
4-5
4
SER
VOP
ACK Specifications and Dimensional Drawings
* 1. Use the SERVOPACK within the surrounding air temperature range. When enclosed in a control panel, internal
temperatures must not exceed the surrounding air temperature range.
* 2. Speed regulation is defined as follows:
The motor speed may change due to voltage variations or amplifier drift and changes in processing resistance
due to temperature variation. The ratio of speed changes to the rated speed represent speed regulation due to
voltage and temperature variations.
* 3. Forward is clockwise viewed from the non-load side of the servomotor. (Counterclockwise viewed from the
load and shaft end)
* 4. The built-in open collector power supply is not electrically insulated from the control circuit in the SERVO-
PACK.
* 5. The DC reactor connection terminals for power supplies designed for minimum harmonics are not included in
SERVOPACKs with capacities of 6 kW or more.
Internal
Func-
tions
Dynamic Brake
Operated at main power OFF, servo alarm, servo OFF or overtravel.
Overtravel Stop
Dynamic brake stop at P-OT or N-OT, deceleration to a stop, or coast to a
stop
Electronic Gear
0.01
≤
B/A
≤
100
Protection
Overcurrent, overvoltage, low voltage, overload, regeneration error, main
circuit detection section error, heat sink overheated, no power supply,
overflow, overspeed, encoder error, overrun, CPU error, parameter error.
LED Display
Charge, Power, five 7-segment LEDs (built-in Digital Operator func-
tions)
CN5 Analog Monitoring
Analog monitor connector built in for monitoring speed, torque and other
reference signals.
Speed: 1 V/1000 min
-1
Torque: 1 V/100% of rated torque
Position error pulses: 0.05 V/1 reference units or 0.05 V/100 reference
units
Communications
Connected Devices
Digital Operator (hand-held model), RS-422A port such as for a personal
computer (RS-232C ports under certain conditions)
1:N Communications
Up to N = 14 for RS-422A ports
Axis Address Setting
Set with parameters.
Functions
Status display, parameter setting, monitor display, alarm trace-back dis-
play, JOG and autotuning operations, speed, torque reference signal and
other drawing functions.
Others
Reverse rotation connection, zero-point search, automatic servomotor ID,
DC reactor connection terminal for harmonic suppressions.
∗
5
Speed reguration
=
No-load motor speed – Total load motor speed
Rated motor speed
×
100
%