5.2 Servomotor Main Circuit Wire Size and Connectors
5-15
5
Specifications and Dimensional Drawings of Cables and Peripheral Devices
5.2.5 SGMGH Servomotor (1000 min
-1
) Connectors for Standard Environments
(1) Without Holding Brakes
(2) With Holding Brakes
4.0 kW and 5.5 kW servomotors require (a) servomotor-end connector and (b) brake power supply connector.
(a) Servomotor-end Connectors
(b) Brake Power Supply Connectors
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Straight
L-shaped
0.3
0.6
0.9
MS3102A18-10P
MS3106B18-10S
MS3108B18-10S
MS3057-10A
1.2
2.0
3.0
MS3102A22-22P
MS3106B22-22S
MS3108B22-22S
MS3057-12A
4.0
5.5
MS3102A32-17P
MS3106B32-17S
MS3108B32-17S
MS3057-20A
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Straight
L-shaped
0.3
0.6
0.9
MS3102A20-15P
MS3106B20-15S
MS3108B20-15S
MS3057-12A
1.2
2.0
3.0
MS3102A24-10P
MS3106B24-10S
MS3108B24-10S
MS3057-16A
4.0
5.5
MS3102A32-17P
MS3106B32-17S
MS3108B32-17S
MS3057-20A
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Straight
L-shaped
4.0
5.5
MS3102A10SL-3P
MS3106A10SL-3S MS3108A10SL-3S
MS3057-4A
Содержание Sigma-II Series
Страница 384: ...8 3 8 Operation...