5 Specifications and Dimensional Drawings of Cables and Peripheral Devices
5.2.9 SGMGH Servomotor (1000 min
-1
) Connectors Conforming to IP67 and European Safety Standards
5-24
(2) 0.3 to 3.0 kW Servomotors With Holding Brakes
Select a cable clamp in accordance with the applied cable diameter.
The straight plug type JA06A-24-10S-J1-EB and L-shaped plug type JA08A-24-10S-J1-EB conform to IP67 Protective
Construction Standard only.
(3) 4.0 kW and 5.5 kW Servomotors With Holding Brakes
The servomotor end connector (a) and brake power supply connector (b) are required.
Select a conduit in accordance with the applied cable diameter.
(a) Servomotor-end Connector
(b) Brake Power Supply Connector
INFO
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Applicable Cable
Range in mm (in)
(For reference)
Straight
L-shaped
0.3
0.6
0.9
JL04V-2E20-15PE-B
JL04V-6A20-15SE-EB
JL04V-8A20-15SE-EB
JL04-2022CK(09)
φ
6.5 to
φ
9.5
JL04-2022CK(12)
φ
9.5 to
φ
13.0
JL04-2022CK(14)
φ
12.9 to
φ
15.9
1.2
2.0
3.0
JL04V-2E24-10PE-B
JL04V-6A24-10SE-EB
or
JA06A-24-10S-J1-EB
JL04V-8A24-10SE-EB
or
JA08A-24-10S-J1-EB
JL04-2428CK(11)
φ
9.0 to
φ
12.0
JL04-2428CK(14)
φ
12.0 to
φ
15.0
JL04-2428CK(17)
φ
15.0 to
φ
18.0
JL04-2428CK(20)
φ
18.0 to
φ
20.0
Capacity
(kW)
Connector on
Servomotor
Plug
Conduit
Applicable Cable
Range in mm
(For reference)
Straight
L-shaped
4.0
5.5
JL04V-2E32-17PE-B
JL04V-6A32-
17SE
ACS-16RL-MS32F ACA-16RL-MS32F
φ
12.0 to
φ
16.0
ACS-20RL-MS32F ACA-20RL-MS32F
φ
16.0 to
φ
20.0
ACS-24RL-MS32F ACA-24RL-MS32F
φ
20.0 to
φ
24.0
ACS-28RL-MS32F ACA-28RL-MS32F
φ
24.0 to
φ
28.0
ACS-32RL-MS32F ACA-32RL-MS32F
φ
28.0 to
φ
32.0
ACS-36RL-MS32F ACA-36RL-MS32F
φ
32.0 to
φ
36.0
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Applicable Cable
Range in mm
(For reference)
Straight
L-shaped
4.0
5.5
CE05-2A10SL-3PC-B
CE05-6A10SL-3SC-
B-BSS
CE05-8A10SL-3SC-
B-BAS
CE3057-4A-1
φ
3.6 to
φ
5.6
Содержание Sigma-II Series