Settings
Set auto control
Settings assistant, setpoints, options
Manual operation
Manual override
Overriding
auto control via
manual intervention.
Double pump operation
Set double pump
External interfaces
Analogue, digital, SSM, SBM
1
2
3
Fig. 34:
Settings menu
NOTICE
There is an arrow
1
above or below the visible menu items if there are more than
four sub-menu items. Turn the operating button in the corresponding direction to
open the sub-menu items on the display.
An arrow
1
above or below a menu area indicates that additional sub-menu items are
available in this area. These sub-menu items are accessible by turning
the oper-
ating button.
An arrow
2
towards the right in a sub-menu item indicates that another sub-menu is
available. Press
the operating button to open this sub-menu.
If there is no arrow to the right, press the operating button to open a settings dialogue.
A note
3
above the “Context” button shows specific functions of the “Context”
menu. Press the “Context” menu button
to open the “Context” menu.
NOTICE
Briefly press the “Back” button
in a sub-menu to return to the previous menu.
Briefly press the “Back” button
in the main menu to return to the “Home
screen”. If there is an error, press the “Back” button
to return to the error display
(“Error messages” section).
If there is an error, press and hold the “Back” button
(> 1 second) from any set-
tings dialogue or from any menu level to return to the “Home screen” or error dis-
play.
10.3.8
Settings dialogues
Settings dialogues have been highlighted with a yellow frame and show the current
setting.
Turn the operating button to the right or left to adjust the highlighted setting.
Press the operating button to confirm the new setting. The focus returns to the menu
you opened.
If you do not turn the operating button before pressing, the previous setting remains
unchanged.
One or more parameters can be set in the settings dialogues.
ƒ
If only one parameter can be set, the focus returns to the menu you opened after
having confirmed the parameter value (pressing the operating button).
ƒ
If several parameters can be set, the focus changes to the next parameter after
having confirmed a parameter value.
If you confirm the last parameter in the settings dialogue, the focus returns to the
menu you opened.
Press the “Back” button
to return the focus to the previous parameter. The
previously changed value will be discarded because it had not been confirmed.
Содержание Stratos GIGA2.0-D
Страница 2: ...Fig I Stratos GIGA2 0 I Stratos GIGA2 0 D DN 40 DN 100 D...
Страница 3: ...Fig II Stratos GIGA2 0 I Stratos GIGA2 0 D DN 40 DN 100 E E D...
Страница 4: ...Fig III Stratos GIGA2 0 I Stratos GIGA2 0 D DN 100 DN 125 D D E...
Страница 5: ...5 Deutsch 6 English 139 Fran ais 270 Nederlands 409...
Страница 548: ......
Страница 549: ......
Страница 550: ......
Страница 551: ......