TROUBLESHOOTING
Table 12. SmartDC Controller - Troubleshooting
Ref.
No�
Display
Description
Possible Causes
Solutions
Condition
Alert, Error or Fault
17
ALERT 9
LOOP OPEN
The HY5B has detected
a lack of continuity in
the loop wire.
Caused by broken loop
wire or wire has come
unplugged from detector.
The loop and lead in wires
should be checked for
problems or replaced.
18
ALERT 10
12C BUS ERROR
The SmartDC Controller
has detected a
communication error
with a HY5B vehicle
detector.
Caused by removal of HY5B
or lack of integrity of the
socket connection. This
message will also indicate
which detector the alert
applies to: Exit Loop (ELD),
Inside Obstruction Loop
(IOLD), Outside Obstruction
Loop (OOLD), or Center
Loop (CLD) - (User Relay
22).
Remove and re-install the
HY5B and press RESET. Replace
the HY5B, if necessary.
19
ALERT 11
DETECTOR
FAULT
The SmartDC Controller
has detected a problem
within a HY5B vehicle
detector.
Caused by a fault within
the HY5B. This message
will also indicate which
detector the alert applies
to: Exit Loop (ELD), Inside
Obstruction Loop (IOLD),
Outside Obstruction Loop
(OOLD), or Center Loop
(CLD) - (User Relay 22).
Remove and re-install the
HY5B and press RESET. Replace
the HY5B, if necessary.
20
ALERT 12
ON TOO LONG
The SmartDC Controller
has an active loop input
(HY5B or box detector
output) for more than 5
minutes.
Caused when the SmartDC
Controller sees an active
loop for more than 5
minutes. The “active” loop
can be actual or false. This
message will also indicate
which detector the alert
applies to: Exit Loop (ELD),
Inside Obstruction Loop
(IOLD), Outside Obstruction
Loop (OOLD), or Center
Loop (CLD) - (User Relay
22).
Check traffic patterns at the
site. The loop and lead-in
wires should be checked for
problems or replaced.
Содержание ALPHA
Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 40: ...40 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 42: ...42 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 44: ...44 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 48: ...48 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 50: ...50 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 52: ...52 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 54: ...54 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 56: ...56 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 167: ...Figure 47 Schematic for Kinetic DC 15 Kinetic 1 and Kinetic DC 10F Kinetic 2 Operator s...
Страница 168: ......
Страница 169: ...Figure 48 Schematic for Kinetic DCS 15 Kinetic 1S and Kinetic DCS 10F Kinetic 2S Solar Operator s...
Страница 170: ......
Страница 180: ......
Страница 182: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com...