SAFETY REQUIREMENTS
Safety Requirements
Automatic gate operators provide user convenience and security. However, because these machines can
produce high levels of force, it is imperative that gate operator system designers, installers and end users
be aware of potential hazards associated with improperly designed, installed, or maintained systems. The
gate operator is only one component of the total gate operating system. It is the joint responsibility of the
architect, site designer, purchaser, installer and end user to verify that the total system is appropriately
configured for its intended use. Additionally, certain municipalities have established licensing, codes
or regulations that regulate automated gate system design and installation. Consult local government
agencies for up-to-date rules and regulations prior to gate system design or installation.
Important Safety Instructions
A moving gate can cause serious injury
or death. Start the gate operator only
when the gate’s travel path is clear.
Hazards, associated with automatic gates, can be reduced with proper site design, installation, and use.
Installers, maintenance crew, and owners/users must read and follow the Important Safety Instructions in
this manual and review all the literature that accompanies the product. It is important that only qualified
installers handle the installation of the Kinetic gate operator. A qualified installer has one of the following:
•
A minimum of three years’ experience installing similar equipment.
•
Proof of attending a Wallace Perimeter Security Technical Training seminar within the past three
years.
•
Significant manufacturer endorsements of technical aptitude in gate operator installation and
operation.
Underwriter Laboratories (UL) and the American Society for Testing and Materials (ASTM) are responsible
for current safety standards and regulations regarding gate operators and automated gates. All aspects of
gate installation must comply with the appropriate safety standard. For the most up-to-date ASTM F2200
Gate and Fence Standards, refer to
. For UL 325 Safety Standard, refer to
.
Содержание ALPHA
Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 40: ...40 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 42: ...42 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 44: ...44 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 48: ...48 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 50: ...50 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 52: ...52 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 54: ...54 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 56: ...56 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 167: ...Figure 47 Schematic for Kinetic DC 15 Kinetic 1 and Kinetic DC 10F Kinetic 2 Operator s...
Страница 168: ......
Страница 169: ...Figure 48 Schematic for Kinetic DCS 15 Kinetic 1S and Kinetic DCS 10F Kinetic 2S Solar Operator s...
Страница 170: ......
Страница 180: ......
Страница 182: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com...