INSTALLING VEHICLE DETECTORS AND LOOPS
Installing Vehicle Detectors and Loops
A vehicle detector passes a small current flow through the “loop” which then becomes an inductive
coil. When a vehicle passes over the loop, the detector senses the resultant drop in the inductance, and
actuates the detector output.
Loop Configurations:
Configurations differ depending on the application. In parking applications, a loop may be as small as 4 x 6
feet (122 x 183cm). In traffic applications employing one of our swing or slide gate operators, the smallest
loop should not be less than 6 x 6 feet (183 x 183cm) in order to detect high bed vehicles.
Rules to Follow for Security Gate Applications:
The side of the loop closest to the gate must be located at least 4 ft (122cm) from the line of travel.
1.
The shortest side of the loop should be between 6 and 8 feet (1.8 and 2.4m) in length. The longest
side of the loop should be between 6 and 20 feet (1.8 x 6.1m) in length. For applications that need to
span a wide area, use several smaller loops. Do not connect more than 200 square feet (18.6 sq. m)
of loop area to a single detector.
2.
In applications with multiple loops, keep each loop at least 6 feet (1.8m) apart. This avoids “cross talk”.
It is possible to have loops closer together by selecting different frequencies. An advantage of using
HySecurity model HY5B detectors is that problematic “cross talk” is not possible.
3.
For greater sensitivity and less chance of false calls caused by the motion of the gate, it is better to
use multiple smaller loops, connected in a series circuit, to one detector instead of a single large loop.
4. To avoid interference, keep loops at least 2 inches (5cm) above any reinforcing steel. Do not route loop
wires with, or in close proximity to, any other conductors, including other loop leads, unless shielded
lead-in cable is used. Never route high voltage circuits in PVC conduit near a loop.
5.
Loop and lead-in wire should be one continuous piece. Avoid splices, if possible. If a splice is necessary
for any reason, “pot” the splice in epoxy or use heat shrink to ensure that the quality of the splice
covering is the same as the original wire jacket.
6.
Use only 14-, 16-, or 18-gauge stranded wire with a direct burial jacket. Cross
-
linked polyethylene
insulation types, such as XLPE or XHHW, will last much longer and are less prone to damage during
installation than conventional insulation types. Preformed loops can be used before road surfacing or
under pavers.
7.
Twist loose tails of lead-in wires tightly, approximately ten times per foot. See Figure 39.
8. Follow this guide for the correct number of turns in the loop:
12 to 20 sq. ft. = 5 turns
20 to 60 sq. ft. = 4 turns
60 to 240 sq. ft. = 3 turns
3.7 to 6.1 sq. m = 5 turns
6.1 to 18.3 sq. m = 4 turns
18.3 to 73.1 sq. m = 3 turns
Figure 39
.
Wire Twist Lead-ins
Содержание ALPHA
Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 40: ...40 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 42: ...42 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 44: ...44 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 48: ...48 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 50: ...50 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 52: ...52 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 54: ...54 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 56: ...56 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 167: ...Figure 47 Schematic for Kinetic DC 15 Kinetic 1 and Kinetic DC 10F Kinetic 2 Operator s...
Страница 168: ......
Страница 169: ...Figure 48 Schematic for Kinetic DCS 15 Kinetic 1S and Kinetic DCS 10F Kinetic 2S Solar Operator s...
Страница 170: ......
Страница 180: ......
Страница 182: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com...