INSTALLING GATE EDGE SENSORS
Installing Gate Edge Sensors
Refer to Figure 44 to help plan the most appropriate placement of the edge sensors being installed. For
sliding gates, one or more contact sensors (edge sensors) must be located at the leading edge, trailing
edge and post-mounted both inside and outside of the sliding gate. Three-sided detectors are ideal for
slide gates. If the clearance of the gate is 6 inches (15cm) or more above the road, then an edge sensor
must be mounted on the bottom edge. Underwriters Laboratories requires that any contact sensor used
as an external entrapment protection device, must be laboratory tested to, and recognized by, the UL 325
Standard.
Drill holes through the edge's mounting channel and through the surface that each gate edge is to be
mounted. Securely fasten every edge sensor. Protect the area wherever a potential pinch point exists for
any type of entrapment. Ensure all exposed pinch points are eliminated or guarded.
Edge sensors that are not attached to the moving gate, such as post mounted sensors, must be wired in
parallel and directly connected to the gate operator:
•
If the gate is sliding open to a wall with less than 16" (41cm) of clearance, mount an edge sensor to
the wall that aligns with the gate when it is in the open position. Always route the leads from the edge
sensors to the gate operator so that they are protected from physical damage.
•
An optional receiver connection method is to connect one edge sensor lead to a COM terminal at the
top, left side of the SmartDC Controller, and the other lead to the EDGE terminal, at the bottom left
side of the controller.
Figure 44. Gate Edge Sensor Installation
Содержание ALPHA
Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 40: ...40 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 42: ...42 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 44: ...44 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 48: ...48 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 50: ...50 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 52: ...52 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 54: ...54 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 56: ...56 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 167: ...Figure 47 Schematic for Kinetic DC 15 Kinetic 1 and Kinetic DC 10F Kinetic 2 Operator s...
Страница 168: ......
Страница 169: ...Figure 48 Schematic for Kinetic DCS 15 Kinetic 1S and Kinetic DCS 10F Kinetic 2S Solar Operator s...
Страница 170: ......
Страница 180: ......
Страница 182: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com...