Group
28
Ignition
systems
Fault tracing
,
Rex-I
-O
R
146 729
146 729
N29
Check ignition coil/power stage ground connec-
tions
Measure resistance
between
terminal B
in 3
-
pole
con-
nector
and
ground. Resistance
must
not
exceed
0.1
ohm. If resistance is too high,
clean
ground
connection
and
/
or
replace
ground
lead as required
.
Measure resistance between terminal A in 2-pole con-
nector
and ground
.
Clean ground connection and/or
place ground
lead as required if resistance
exceeds
0.1
o
hm
.
224
3
•
N30
Check signal lead
ignition
stage and control unit
Connect
buzzer between terminal B in 2-pole
connec-
tor
and
terminal 16 in
control
unit
connector.
Buzzer
should sound
if lead is intact
.
N31
Persistent failure of
engine
to
start
despite
of
faults or
correction
of fault(s} which have been located
indicates internal fault in
control
unit
or
power
stage
.
Verify by installing new
control
unit
or
new power
stage.
Rein
s
tall ignition
coil.
Reassemble
control
unit
connec-
tor and reconnect to unit.
Reconnect ignition
coillpower stage connectors
.
Check
that no new fault
codes are
displayed.