Indicated on display
Possible cause of fault Possible effects
Fault remedy
Signal too high
◆
Wire open circuit or
wire has short to
earth
◆
Throttle valve potenti-
ometer -G69- defec-
tive
◆
Regeneration is
locked
– Check -J338-
, final
control diagnosis
– -J338- Check.
– Check electrical con-
nection to sensor
00304/P0130
Bank 1 - probe 1
Electrical fault in current
circuit
◆
Open circuit or line
short-circuit
◆
Lambda probe -G39-
defective
◆
Zero quantity calibra-
tion, calculation of die-
sel particulate filter
load, exhaust gas
temperature regula-
tion, FMO locked
◆
Regeneration of NOx
storage catalytic con-
verter is locked
– -G39- Check.
– Check electrical con-
nection to sensor
00309/P0135
Bank 1 - probe 1, heating
element circuit
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
3
3 List of fault codes
39