– Connect multimeter to contacts 1 + 2 of sender using test
leads from -V.A.G 1594- to measure resistance.
Scale -A- shows resistance values for a temperature range of
0…50°C, and scale -B- shows the values for a temperature
range of 50…100°C.
Examples:
◆
30°C is on scale -A- and corresponds to a resistance of
1500…2000 Ω.
◆
80°C is on scale -B- and corresponds to a resistance of
275…375 Ω.
If the specification is not attained:
– Renew intake air temperature sender
-G42-
together with
charge pressure sender -G31-.
– Then, read event memory of engine control unit, and clear
, read event memory.
If specification is attained:
Checking voltage supply
– Connect multimeter to contacts 1 + 3 of connector using test
leads from -V.A.G 1594- to measure voltage.
– Switch on ignition. Specification: at least 4.8... 5.2 V
– Switch off ignition.
– Check wiring of intake air temperature sender as follows:
– Using adapter cable -V.A.G 1598/39-2-, connect test box
-V.A.G 1598/42- to wiring harness of control unit
The engine control unit is not connected by this action.
– Check wiring between test box and connector for open cir-
cuit referring to current flow diagram.
◆
Contact 1 + socket 66
◆
Contact 2 + socket 30
● Cable resistance: max. 2.0 Ω.
– Also check wiring for short to one another, short to battery
earth/engine earth and short to battery positive. Specifica-
tion: ∞ Ω
3
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
406
Repair Group 23 - Mixture preparation - injection