27 - Starter, current supply, CCS
1
Starter -B-
WARNING
Adhere to the general safety regulations and the notes on
repair work on the engine!
Observe rules for cleanliness
.
Connections on solenoid switch
Starter -B- not turning
Starter -B- turning too slowly and not cranking engine properly
.
Removing and installing starter -B-
1.1
Connections on solenoid switch
1 - Terminal 30 - from battery -A-
2 - Terminal 50 - from ignition/starter switch -D-
3 - Connection for coil
1.2
Starter -B- not turning
Special tools and workshop equipment required
◆
Auxiliary measuring set -V.A.G 1594-
◆
Hand multimeter -V.A.G 1526- or multimeter -V.A.G 1715-
◆
Current flow diagram
Test prerequisites
● Fuses must be OK.
● Battery charged and tested.
● Earth connections OK
● All electrical consumers must be switched off.
● The connections on the solenoid switch/earth strap – be-
tween engine, power unit and battery – must be firmly seat-
ed and must not be corroded.
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
3
1 Starter -B-
467